Assisting a trade customer with DPF issues on a sales vehicle.
The van had a previous diagnostic “scan “ by a local garage using a generic code reader.
Using dealer level diagnostic kit we efficiently diagnosed a faulty component that had resulted in failed DPF regenerations.
The Component was replaced followed by a 3 stage on vehicle DPF clean reducing the DPF pressure from 3 Kpa at idle to 0 kpa allowing natural regeneration to take place.