This vehicle was suffering from limp mode due to a blocked DPF with 43 mbar of DPF back pressure at idle. Our 3 Stage cleaning service soon got the back pressure down to a nice and clean 6 mbar.
Our pre clean diagnostic highlighted the following faults:
…
P2458 Regen Duration
P0671 Glow Plug Circuit
P2453 DPF Pressure Sensor Circuit
Live data analysis also highlighted the vehicle had not regenerated for 702 KM and the calculated DPF saturation was 194%. Further diagnostic interrogation confirmed the DPF pressure sensor was faulty and all 4 glow plugs were open circuit. The route cause of the DPF blockage was down to these failed components preventing successful regeneration.
We don’t just clean DPF’s, we identify any underlying issues in order to prevent premature blocking of the DPF in the future.
For professional DPF Cleaning in the Bristol area please contact the DPF Doctors @ Avon Tuning